ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - ON-VEHICLE SERVICE
UREA INJECTOR ASSEMBLY CHECK
N502630660000G00ENG
Measurement of Resistance Between Terminals
CAUTION:
Put the disconnected connector in a plastic bag respectively to prevent dust from adhering to them.
Disconnect the urea injector assembly connector.
Measure the resistance between terminals.
Standard value: 11.4 to 12.6 Ω (at 20°C)
Measure the resistance between urea injector body and either terminal No. 1 or terminal No. 2 of the connector at the urea injector assembly (check short to earth in the internal circuit of the urea injector).
Normal condition: No continuity
If the resistance is deviates from the standard value, replace the urea injector assembly.
Connect the urea injector assembly connector.
Check The Urea Pressure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to the "ON" position.
Check the data list item No. 15: SCR system condition and item No. 50: Urea pressure sensor (filtered value).
Normal condition: SCR system condition reaches to "Pressure build-up completed", and Urea pressure sensor (filtered value) reaches to "5,000 to 7,000 hPa".
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
Check The Urea Injector Assembly Condition
Remove the urea injector assembly from the catalytic converter without disconnecting the urea injector assembly connector and the urea line tube A from the urea injector assembly (Refer to UREA INJECTOR, UREA FEED TUBE REMOVAL AND INSTALLATION).
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to the "ON" position (but do not start the engine).
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From UDCU Screen, select "Special Function".
From Special Function Screen, select "Test".
Carry out the "Item No. 4: Urea pumping and Dosing test" from Test Screen of the M.U.T.-III SE.
NOTE:
It takes approximately 30 seconds until the AdBlue® is injected from the urea injector assembly after the urea pumping and injection test is performed because it takes time until the urea line tube is filled with the AdBlue®.
CAUTION:
If the AdBlue® is adhered to the vehicle, wipe the area with a wet cloth.
Check the injection status of the urea injector assembly.
Normal condition: The AdBlue® is injected from each injection port of the urea injector assembly equally.
Stop "Item No. 4: Urea pumping and Dosing test".
If AdBlue® is not equally injected from each injection port of the urea injector assembly, replace the urea injector assembly.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
Install the urea injector assembly in the original places.
Check The Urea Leaks
Remove the urea injector assembly from the catalytic converter without disconnecting the urea injector assembly connector and the urea line tube A from the urea injector assembly (Refer to UREA INJECTOR, UREA FEED TUBE REMOVAL AND INSTALLATION).
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to the "ON" position (but do not start the engine).
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From UDCU Screen, select "Special Function".
From Special Function Screen, select "Test".
Carry out the "Item No. 6: Urea leak test" from Test Screen of the M.U.T.-III SE.
CAUTION:
If the AdBlue® is adhered to the vehicle, wipe the area with a wet cloth.
Check for leakage from the urea injector nozzle and urea line tube.
Normal condition: During the urea leak test, the AdBlue® does not leak from the urea injector nozzle or urea line tube.
If AdBlue® is leaking from each injection nozzle or urea line tube, replace the urea injector assembly or urea line tube.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.
Install the urea injector assembly in the original places.
BookmarkedToo many bookmarks. Please delete and bookmark again.