ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P203A-11 Reductant level sensor A
Diagnosis Procedure: P203A-11
N502631270000100ENG
1.
Check other diagnosis code
Check whether the following diagnosis code is set (Refer to
METHOD OF READING AND ERASING DIAGNOSIS CODES
).
P203A-01: Reductant level sensor A
Is diagnosis code No. P203A-01 set?
YES
Perform the troubleshooting of the diagnosis code No. P203A-01 (Refer to
DTC Description: P203A-01
).
NO
GO TO 2.
2.
Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to
DTC Description: P203A-11
).
Is diagnosis code No. P203A-11 set?
YES
Replace the urea tank assembly [integrated with urea pump module (TLC sensor)] (Refer to
UREA TANK REMOVAL AND INSTALLATION
).
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident –
INTERMITTENT INCIDENT
).
Bookmarked
Too many bookmarks.
Please delete and bookmark again.
×