Disconnect the DCU connector, then reconnect it securely. Then GO TO 4.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
4.Check other system diagnosis code
NOTE:
The operating time of the urea injector cooling system is calculated from the values of exhaust temperature sensor No. 2 and A/C condenser temperature sensor (ambient temperature sensor). After repairing the urea injector assembly, check that there is no malfunction in the exhaust temperature sensor No. 2 and the ambient temperature sensor, as the cause of the failure of the urea injector assembly may be due to the urea injector cooling system not working.
Check whether the following engine control unit (engine-ECU) diagnosis code sets related to exhaust temperature sensor No. 2 and ambient temperature sensor.
Diagnosis code No. P242C-00: Exhaust gas temperature sensor 3 bank 1
Diagnosis code No. P242D-00: Exhaust gas temperature sensor 3 bank 1
Diagnosis code No. U15C1-00: CAN communication (ambient temperature)
Is any diagnosis code set?
YES
Troubleshoot the diagnosis code (Refer to Engine – Diesel Fuel <4N1> – Troubleshooting – DIAGNOSIS CODE CHART). Then GO TO 5.
The urea injector cooling system uses the battery power to drive the ENG cooling water pump (electric water pump) after the engine has stopped. The cause of the failure of the urea injector assembly may be due to insufficient drive time of the electric water pump due to lack of power caused by battery degradation. So after repairing the urea injector assembly, check that there is no malfunction in the battery.
Check the battery (Refer to Electrical & Power Control – Chassis Electrical – Battery – On-vehicle Service – DIAGNOSIS TROUBLESHOOTING FLOW).
Is the check result normal?
YES
Check is end.
NO
Repair or replace the defective parts.