2.Check short circuit to earth between DCU and urea pump (urea supply pump) circuit
Disconnect DCU connector and urea pump connector.
Check the harness side.
Check continuity between DCU connector and body earth.
(+) | (–) | Continuity |
DCU |
Connector | Terminal |
A-129 | 11 | Body earth | No continuity |
33 |
Check harness wire and connector damage between DCU connector and urea pump connector.
DCU | Urea pump | Damage check |
Connector | Terminal | Connector | Terminal |
A-129 | 11 | G-54 | 5 | Good condition |
33 | 4 |
Is the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Diagnosis code recheck after erasing diagnosis code
Is diagnosis code No. P208A-11 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident –
INTERMITTENT INCIDENT).