ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20B9-11 Reductant heater A
Diagnosis Procedure: P20B9-11
N502631960000H00ENG
1.Check urea line tube heater
Check urea line tube heater (Refer to UREA LINE TUBE HEATER CHECK).
Is the check result normal?
YES
NO
Replace the urea line tube A and/or urea line tube B (Refer to UREA INJECTOR, UREA FEED TUBE REMOVAL AND INSTALLATION).
2.Check fuse
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Check the following fuse in the fusible link, fuse holder 2.
    Location
    Signal name
    Fuse No.
    Capacity
    Fusible link, fuse holder 2
    DCU
    F29
    15 A
Is the check result normal?
YES
NO
Perform the procedures for a blown fuse (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – INSPECTION SERVICE POINTS FOR A BLOWN FUSE).
3.Check continuity of DCU power supply line
  1. Disconnect the urea SCR relay connector and DCU connector.
  2. Check the harness connector side.
  3. Check continuity between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-61
    4
    A-129
    5
    Continuity exists (2 Ω or less)
Is the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Check short circuit to earth between DCU and urea line tube heater
  1. Disconnect DCU connector and urea heater tube connector.
  2. Check the harness side.
  3. Check continuity between DCU connector and body earth.
    (+)
    (–)
    Continuity
    DCU
    Connector
    Terminal
    A-129
    6
    Body earth
    No continuity
Is the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
5.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P20B9-11).
Is diagnosis code No. P20B9-11 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).