ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20E8-00 Reductant pressure
DTC Description: P20E8-00
N502632070000900ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P20E8-00
Reductant pressure
[Urea pressure too low]
A
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU supply voltage is 10 V or more.
  • At least 1 second has passed since the DCU was activated.
  • After the urea pump (supply pump) is activated.
Signal (terminal)
–
Threshold
  • The pressure buildup is not finished when duration of pressure buildup exceeds 500 seconds.
or
  • The pressure buildup is not finished when number of pump stroke exceeds 1,700.
Diagnosis delay time
None
B
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU supply voltage is 10 V or more.
  • At least 1 second has passed since the DCU was activated.
  • After the urea pump (supply pump) is activated.
Signal (terminal)
–
Threshold
Urea pressure is lower than 5,000 hPa (when pressure sensor is available) or 4,600 hPa (when pressure sensor is failed).
Diagnosis delay time
None
POSSIBLE CAUSE
  • Failed urea feed tube A and/or B (leakage)
  • Failed urea injector assembly (injector stuck in open state)
  • Failed urea injector cooling system (clogging in cooling passage, failed water control valve, leakage in urea injector due to overheat)
  • Failed urea pump (integrated with urea supply pump and urea back flow pump) (failed urea supply pump, urea back flow pump stuck in open state、leakage in piping inside urea pump)
FAIL-SAFE AND BACKUP FUNCTION
Urea SCR system shutdown. → Urea dosing is stopped.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. Carry out the forcible DPF regeneration (Refer to FORCIBLE DPF REGENERATION).
  2. 5 seconds or more later after the ignition switch has been in "ON" position.
  3. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P20E8-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.