(+) | (–) | Continuity | |
DCU | |||
Connector | Terminal | ||
A-129 | 4 | Body earth | Continuity exists (2 Ω or less) |
DCU | Body earth point | Damage check | |
Connector | Terminal | No. | |
A-129 | 4 | 19 | Good condition |
Location | Signal name | Fuse No. | Capacity |
Fusible link, fuse holder 2 | DCU | F32 | 15 A |
F29 | 15 A | ||
F27 | 15 A |
Urea SCR relay | DCU | Continuity | ||
Connector | Terminal | Connector | Terminal | |
A-61 | 4 | A-129 | 1 | Continuity exists (2 Ω or less) |
5 | ||||
3 | ||||
(+) | (–) | Continuity | |
DCU | |||
Connector | Terminal | ||
A-129 | 1 | Body earth | No continuity |
5 | |||
3 | |||