Diagnosis Code No. | M.U.T.-III SE Screen Item [Diagnosis item] | Diagnosis Code Detection Condition | |
P24AE-12 | PM Sensor Circuit High [PM sensor circuit high] | Diagnosis condition | 220 seconds or more have passed since the PM measurement was started. |
Signal (terminal) | PM sensor | ||
Threshold | The self-diagnosis result indicating malfunction of the negative-side electrode is received from the PM sensor via CAN communication for 3 seconds or more. | ||
Diagnosis delay time | 3 seconds. | ||