ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P2BA9-00 NOx exceedance
Diagnosis Procedure: P2BA9-00
N502633250000F00ENG
1.Check other diagnosis code
Check whether the following diagnosis codes are set (Refer to METHOD OF READING AND ERASING DIAGNOSIS CODES).
  • P203A-01: Reductant level sensor A
  • P206A-11: Reductant quality sensor
  • P206A-12: Reductant quality sensor
  • P206A-1F: Reductant quality sensor
  • U0619-00: Lost communication(reductant level sensor A)
Is any diagnosis code set?
YES
Perform the troubleshooting of the diagnosis code (Refer to DIAGNOSIS CODE CHART).
NO
2.Diagnosis code recheck after erasing diagnosis code
Check if the diagnosis code is set again (Refer to DTC Description: P2BA9-00).
Is diagnosis code No. P2BA9-00 set?
YES
Change all the AdBlue® (Refer to AdBlue CHANGE).
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).