ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P33FD-1E Supply pump
DTC Description: P33FD-1E
N502633330000800ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P33FD-1E
Supply pump
[Supply pump current implausible]
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU power supply voltage is more than 10 V.
  • Urea tank temperature is greater than –5°C.
  • The difference of following 3 sensors is 10°C or less:
    • Ambient temperature.
    • Engine coolant temperature.
    • Exhaust gas temperature sensor No. 2.
  • 8 hours or more have passed since the last time the ignition switch was turned "LOCK" (OFF) position (Cold start condition).
Signal (terminal)
Urea supply pump
Threshold
The difference between the calculated resistance value and the actual resistance value is 25 % or more.
Diagnosis delay time
None.
POSSIBLE CAUSE
  • Open/short circuit or harness damage in urea supply pump power supply circuit or loose connector contact.
  • Open circuit or harness damage in urea supply pump earth circuit or loose connector contact.
  • Failed urea pump (integrated with urea supply pump).
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position.
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P33FD-1E set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.