Item No. | Data item | Unit·Condition |
1 | ODO/TRIP METER | km |
2 | DTC count | count |
3 | Protection control operating state(urea injector 1) | ON or OFF |
4 | Urea injector 1 tip temperature | °C |
5 | SCR1 ammonia absorption | g |
6 | SCR2 ammonia absorption | |
7 | SCR1 catalyst average temperature | °C |
8 | SCR2 catalyst average temperature | |
9 | Urea consumption rate | g/km |
10 | Exhaust gas flow rate | kg/h |
11 | NOx sensor 1 received heat quantity | kJ |
12 | NOx sensor 3 received heat quantity | |
13 | PM sensor received heat quantity | |
14 | NOx sensor 1 heat quantity threshold | |
15 | NOx sensor 3 heat quantity threshold | |
16 | PM sensor heat quantity threshold | |
17 | SCR system condition | Initial state, No pressure control, Pressure build-up, Pressure build-up completed, Decompression state, Air venting condition, Initial replenishment state, Sucking back completed state, Sucking back state, Ignition ON state |
18 | SCR system sub condition | No sub state, Pressure build-up preparation, Ventilation, Normal decompression, Decompression injector 1 open, Pressure sensor replacement, Decompression injector 2 open, System circulation, Successful initial filling, Initial decompression state, Decompressed state, Pump valve open state, Heat A(Urea tank-Piping), Defrost confirm supply pump, Thaw confirm suction pump, Heat B(hydro connector), Defrost confirm hydro connector, Urea pump re thawing, Defrost confirm urea pump |
19 | Urea tank level | mm |
20 | Urea injector 1 desired dosing quantity | mg/s |
21 | Urea backflow pump operating status | Deactivated, Freezing and defrosting, Pump active, Anti-freeze heating or Backflow pump passage fully open |
22 | NOx sensor 1 signal enable flag | ON or OFF |
23 | NOx sensor 3 signal enable flag | |
24 | Ignition switch | |
25 | PM sensor temperature | °C |
26 | Urea tank frozen state | Not frozen, Temperature retention mode, Suspected tank freeze, Tank freeze detection or NONE |
27 | Estimated ammonia concentration downstream SCR1 | ppm |
28 | Estimated ammonia concentration downstream SCR2 | |
29 | Urea injection control status | Stop urea injection, Permission for urea injection, Restricted(NH3 slip), Stop(DPF regen requirement), Urea inj permit(regen prog), Stop(DPF regen temperature high), Restricted(exh system fail), Stop(regen required exh fail), Restricted(exh fail DPF regen) |
30 | Urea pressure sensor(filter value) | hPa |
31 | Urea level sensor status | No signal, Signal NG(short time), Signal OK(reception low), Signal OK(reception medium), Signal OK(reception high) or Signal OK(maximum reception) |
32 | Fuel injection quantity | mg/hub |
33 | Urea temperature sensor status | Available or Not available |
34 | Urea concentration signal status | NG(no signal), NG(sonar low quality), NG(sonar low constant), OK(sonar high quality small), OK(sonar high quality medium) or OK(sonar high quality large) |
35 | Engine speed | r/min |
36 | Vehicle speed | km/h |
37 | Ambient pressure | kPa |
38 | Battery voltage | V |
39 | Ambient temperature | °C |
40 | Urea Concentration | % |
41 | Urea Tank Temperature | °C |
42 | NOx sensor 1 detect concentration | ppm |
43 | NOx sensor 3 detect concentration | |
44 | Urea tank remaining volume(L) | L |
45 | Vehicle acceleration(front/rear G) | m/s2 |
46 | Vehicle acceleration(lateral G) | |
47 | Duty of electrical water pump | % |
48 | SCR1 target ammonia absorption | g |
49 | SCR2 target ammonia absorption | |
50 | DPF operation status | Normal mode, Regeneration mode or SCR Catalyst warm up mode |
51 | PM sensor status | Initialize(Sensor regeneration), Measurement, Sensor not ready or Regeneration finished |
52 | PM sensor current | uA |
53 | Number of moving detection of urea injector 1 valve | count |
54 | Urea tube heater current | A |
55 | Coolant temperature | °C |
56 | Urea tank level | % |
57 | Urea supply pump current(Pump lift stopped) | mA |
58 | O2 value(NOx sensor 1) | – |
59 | O2 value(NOx sensor 3) | |
60 | EGR valve rate | % |
61 | Exhaust gas temperature sensor 1 | °C |
62 | Exhaust gas temperature sensor 2 | |
63 | Exhaust gas temperature sensor 3 | |
64 | Urea tank heater current | A |