ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - SYMPTOM PROCEDURES - Diagnose shorts between CAN_H and L lines (ENG-LOCAL CAN)
DESCRIPTION: Diagnose shorts between CAN_H and L lines (ENG-LOCAL CAN)
N502634800000100ENG
CAUTION:
When servicing a CAN bus line, earth yourself by touching a metal object such as an unpainted water pipe. If you fail to do, a component connected to the CAN bus line may be broken.
TROUBLE JUDGEMENT CONDITIONS
When all of the following conditions are met, the M.U.T.-III SE determines that a short circuit is present between CAN_L and CAN_H lines.
The M.U.T.-III SE cannot receive the periodic transmission data from DCU.
The voltage between ENG-LOCAL CAN (CAN_L and CAN_H lines) is 1.0 V or more, 4.0 V or less.
The resistance at ENG-LOCAL CAN (CAN_L and CAN_H lines) is 2 Ω or less.
PROBABLE CAUSES
Malfunction of the wiring harness
Malfunction of the connector
Malfunction in the ECUs or sensors which are interconnected via ENG-LOCAL CAN (internal error) (DCU, Engine-ECU, NOx sensor No. 1, NOx sensor No. 3, PM sensor).