ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - SYMPTOM PROCEDURES - DCU power supply system (Communication between M.U.T.-IIISE and DCU is not possible)
DIAGNOSIS PROCEDURE: DCU power supply system (Communication between M.U.T.-III SE and DCU is not possible)
N502634840000G00ENG
1.Check urea SCR relay itself
Check urea SCR relay itself (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – RELAY INSPECTION).
Is the check result normal?
YES
NO
Replace the urea SCR relay.
2.Check DCU power supply circuit
  1. Disconnect DCU connector.
  2. Check the harness connector side.
  3. Turn the ignition switch to the "ON" position.
  4. Check voltage between DCU connector and body earth.
    (+)
    (–)
    Voltage
    DCU
    Connector
    Terminal
    A-129
    66
    Body earth
    Battery voltage
Is the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
3.Check DCU earth circuit
  1. Disconnect DCU connector.
  2. Check the harness connector side.
  3. Check continuity between DCU connector and body earth.
    (+)
    (–)
    Continuity
    DCU
    Connector
    Terminal
    A-129
    4
    Body earth
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between DCU connector and body earth.
    DCU
    Body earth point
    Damage check
    Connector
    Terminal
    No.
    A-129
    4
    19
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Check power supply circuit between urea SCR relay connector and DCU connector
  1. Disconnect electric urea SCR relay connector and DCU connector.
  2. Check the harness connector side.
  3. Check continuity between urea SCR relay connector and DCU connector.
    (+)
    (–)
    Continuity
    Urea SCR relay
    DCU
    Connector
    Terminal
    Connector
    Terminal
    A-61
    3
    A-129
    23
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-61
    3
    A-129
    23
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
5.Check fuse
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Check the following fuse in the fusible link, fuse holder 2.
    Location
    Signal name
    Fuse No.
    Capacity
    Fusible link, fuse holder 2
    DCU
    F32
    15 A
    F29
    15 A
    F27
    15 A
Are the check result normal?
YES
NO
Perform the procedures for a blown fuse (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – INSPECTION SERVICE POINTS FOR A BLOWN FUSE).
6.Check continuity of DCU power supply line
  1. Disconnect the urea SCR relay connector and DCU connector.
  2. Check the harness connector side.
  3. Check continuity between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-61
    4
    A-129
    1
    Continuity exists (2 Ω or less)
    5
    3
  4. Check harness wire and connector damage between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-61
    4
    A-129
    1
    Good condition
    5
    3
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
7.Check power supply circuit between fuse block (J/B) connector and DCU connector
  1. Disconnect fuse block (J/B) connector and DCU connector.
  2. Check the harness connector side.
  3. Check continuity between fuse block (J/B) connector and DCU connector.
    (+)
    (–)
    Continuity
    Fuse block (J/B)
    DCU
    Connector
    Terminal
    Connector
    Terminal
    C-310
    2
    A-129
    66
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between fuse block (J/B) connector and DCU connector.
    Fuse block (J/B)
    DCU
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    C-310
    2
    A-129
    66
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
8.Check the trouble symptom
Does the trouble symptom persist?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
BookmarkedToo many bookmarks.
Please delete and bookmark again.