UREA TANK LEVEL SENSOR/QUALITY SENSOR SONAR TESTN502634930000100ENG

NOTE:
The urea tank level sensor and quality sensor measure the urea tank level and urea water concentration by outputting ultrasonic signals and monitoring the echo signals.
Normally, it is necessary to drive a certain distance until the diagnosis is completed, however by executing this test command, it is possible to complete the diagnosis even if the vehicle is stopped.
Make sure the diagnosis codes P203A-1F or P206A-1F are not set using M.U.T.-III SE. If set, carry out the troubleshooting for the set codes and solve the problems. (Refer to
DIAGNOSIS CODE CHART)
YES
NO
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to the "ON" position.
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From UDCU Screen, select "Special Function".
From Special Function Screen, select "Urea level/quality sensor sonar test".
Carry out the "Item No. 1: Urea level/quality sensor sonar test" from Urea level/quality sensor sonar test Screen.
Wait for 30 seconds or more.
After turning the ignition switch to the "LOCK" (OFF) position, remove the M.U.T.-III SE.