Disconnect the harness connector from the solenoid valve.
Connect a hand vacuum pump to solenoid valve nipple A.
Apply battery voltage to the solenoid valve connector and check that the air pressure condition becomes as shown in the table below by operating the hand vacuum pump.
Battery voltage
Solenoid valve condition
Normal condition
Applied
Nipple A – B opened
Negative pressure maintained
Not applied
Nipple A – C opened
Negative pressure leaks
Measure the resistance of the solenoid valve.
Standard value: 36 – 46 Ω