1.CHECK LOCK-UP CONTROL SOLENOID (SLU) CIRCUIT
Disconnect the A/T-ECU connector.
Measure the resistance between the A/T-ECU connector terminals at the harness side.
A/T-ECU | Resistance |
Connector | Terminal |
G-38 | 4 | 5 | 5.0 to 5.6 Ω (at 20°C) |
Check the continuity between the A/T-ECU connector and body earth at the harness side.
(+) | (-) | Continuity |
A/T-ECU |
Connector | Terminal |
G-38 | 4 | Body earth | No continuity |
5 |
Is the inspection result normal?
YES
NO
2.CHECK LOCK-UP CONTROL SOLENOID (SLU) CIRCUIT WIRING HARNESS (SHORT)
Disconnect the A/T-ECU connector and the A/T control solenoid valve assembly connector.
Check the continuity between the A/T-ECU connector terminals at the harness side.
A/T-ECU | Continuity |
Connector | Terminal |
G-38 | 4 | 5 | No continuity |
Check the continuity between the A/T-ECU connector terminals at the harness side.
A/T-ECU | Continuity |
Connector | Terminal | Connector | Terminal |
G-38 | 4 | G-36, G-37 and G-38 | Other terminals | No continuity |
5 |
Is the inspection result normal?
YES
NO
Repair the connector(s) or wiring harness.
3.CHECK LOCK-UP CONTROL SOLENOID (SLU)
Is the inspection result normal?
YES
NO
4.PERFORM DTC CONFIRMATION PROCEDURE
Is the DTC set?
YES
NO