RESTRAINTS - SUPPLEMENTAL RESTRAINT SYSTEM (SRS) - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES<SRS-ECU> - B100E-1B Knee air bag module RH
Diagnosis Procedure: B100E-1B
N508186830000100ENG
WARNING:
  • Before servicing, ignition switch OFF, disconnect battery negative terminal, and wait at least 3 minutes or more. (To discharge backup capacitor.)
  • Never use unspecified tester or other measuring device.
1.CHECK HARNESS CONNECTOR
Check the harness connector.
Is the inspection result normal?
YES
NO
Replace harness connector.
2.CHECK WIRING HARNESS
Check the wiring harness externals.
Is the inspection result normal?
YES
NO
Replace wiring harness.
3.REPLACE KNEE AIR BAG MODULE RH
  1. Replace knee air bag module RH. Refer to KNEE AIR BAG MODULE(S) REMOVAL AND INSTALLATION.
  2. Perform DTC confirmation procedure. Refer to DTC Description: B100E-1B.
Is DTC detected?
YES
NO
INSPECTION END
4.REPLACE SRS-ECU
  1. Perform DTC confirmation procedure. Refer to DTC Description: B100E-1B.
Is DTC detected?
YES
NO
INSPECTION END