HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - A/C CONTROL UNIT
A/C CONTROL UNIT REMOVAL AND INSTALLATION <MANUAL A/C, COOLER>
N509000240000H00ENG
CAUTION:
When the A/C control unit is replaced, perform the additional service procedures. Refer to ADDITIONAL SERVICE WHEN REPLACING A/C-ECU.
Pre-removal and Post-installation Operation
Removal steps
1.
A/C-ECU
2.
Air mixing damper control cable connection <manual A/C>
3.
Mode selection damper control cable connection
4.
Outside/Inside air selection damper control cable connection
5.
A/C controller assembly
INSTALLATION SERVICE POINTS
>>A<< OUTSIDE/INSIDE AIR SELECTION DAMPER CONTROL CABLE CONNECTION
Set the outside/inside air selection damper to the inside air recirculation position.
Set the outside/inside air selection lever on the heater control panel to the inside air recirculation position.
Route the cable as shown, and engage the cable end with the outside/inside air selection link pin of the heater assembly.
Insert the cable into the clip while engaging the cable E-ring with the locator in the heater assembly.
Operate the inside/outside air changeover lever on the heater control panel from the inside air recirculation to the outside air positions and vice versa to check that the knob and its linkage run smoothly all the way.

>>B<< MODE SELECTION DAMPER CONTROL CABLE CONNECTION
Check that the air outlet changeover damper lever is at the DEF position.
Set the air outlet changeover knob on the heater control panel to the DEF position.
Route the cable as shown, and engage the cable end with the mode link pin of the heater assembly.
Insert the cable into the clip while engaging the cable E-ring with the locator in the heater assembly.
Operate the air outlet changeover knob to check that it rotates from the FACE to the DEF, and from the DEF to the FACE positions smoothly.
When the blower unit is running at high speed with the knob set to the FACE position, check that no extra air leaks from the footwell outlet (or duct) of the heater assembly.

>>C<< AIR MIXING DAMPER CONTROL CABLE CONNECTION
Set the Temperature control dial of the heater control assembly to MAX HOT position.
Turn the air mixing damper lever of heater assembly to the MAX HOT position (Turn the damper lever to the left until it stops.) and then install the cable.
Route the cable as shown, and engage the cable end with the temperature adjusting link pin of the heater assembly.
Insert the cable into the clip while engaging the cable E-ring with the locator in the heater assembly.
After all of the components have been installed, operate the temperature adjusting knob from HOT to COOL and vice versa. The temperature adjusting linkages of the heater assembly should move smoothly from end position to end position.