HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<MANUAL A/C> - DIAGNOSIS CODE PROCEDURES - B24A4-11 Evap temperature sensor (short circuit)
Diagnosis Procedure: B24A4-11
N509001600000900ENG
1.CHECK FIN THERMO SENSOR SIGNAL
  1. Ignition switch ON.
  2. Check voltage between A/C-ECU harness connector.
    A/C-ECU
    Voltage
    Connector
    Terminal
    (+)
    (-)
    C-06
    28
    23
Is the inspection result normal?
YES
NO
2.CHECK FIN THERMO SENSOR POWER SUPPLY
  1. Ignition switch "LOCK" (OFF) position.
  2. Disconnect fin thermo sensor connector.
  3. Ignition switch ON.
  4. Check voltage between fin thermo sensor harness connector and body earth.
    (+)
    (-)
    Voltage
    (Approx.)
    Fin thermo sensor
    Connector
    Terminal
    C-104
    1
    Body earth
    5 V
Is the inspection result normal?
YES
NO
3.CHECK FIN THERMO SENSOR
Check fin thermo sensor. Refer to Diagnosis Procedure: Fin thermo sensor.
Is the inspection result normal?
YES
NO
4.CHECK FIN THERMO SENSOR POWER SUPPLY CIRCUIT FOR SHORT
  1. Ignition switch "LOCK" (OFF) position.
  2. Disconnect A/C-ECU connector.
  3. Check continuity between fin thermo sensor harness connector and body earth.
    Fin thermo sensor
    (-)
    Continuity
    Connector
    Terminal
    C-104
    1
    Body earth
    Not existed
Is the inspection result normal?
YES
NO
Repair harness or connector.
BookmarkedToo many bookmarks.