1.CHECK FIN THERMO SENSOR
Ignition switch "LOCK" (OFF) position.
Check resistance between fin thermo sensor terminals. Refer to applicable table for the normal value.
Terminal | Condition | Resistance: kΩ |
Temperature: °C |
H-03 | −20 | 14.06 |
−10 | 8.12 |
0 | 4.85 |
10 | 2.96 |
20 | 1.87 |
25 | 1.50 |
30 | 1.21 |
40 | 0.81 |
Is the inspection result normal?
YES
NO