HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - SYMPTOM PROCEDURES - AIR VOLUME OF THE REAR CIRCULATOR CAN NOT BE CHANGED. (FAN MORTOR WORKS)
Diagnosis Procedure: Air volume of the rear circulator can not be changed. (Fan mortor works)
N509002390000100ENG
1.CHECK REAR CIRCULATOR CONTROL PANEL CONNECTOR AND REAR CIRCULATOR CONNECTOR FOR OPEN AND SHORT
Check the continuity between the rear circulator control panel connector and rear circulator connector.
Rear circulator control panel
Rear circulator
Continuity
Connector
Terminal
Connector
Terminal
E-05
4
E-08
2
Existed
9
1
Existed
Check the continuity between the rear circulator control panel connector terminals.
To check malfunction symptom before repair: Refer to General information - General - Basic inspection - Service information for electrical incident - INTERMITTENT INCIDENT.