HEATER, AIR CONDITIONER AND VENTILATION - HEATER, AIR CONDITIONER AND VENTILATION - TROUBLESHOOTING<AUTO A/C> - CIRCUIT DIAGNOSIS PROCEDURE - ION GENERATOR
Diagnosis Procedure: Ion generator
N509002640000400ENG
1.CHECK ION GENERATOR CONTROL SIGNAL CIRCUIT (OPEN CIRCUIT, SHORT TO EARTH)
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Disconnect ion generator harness connector and A/C-ECU harness connector.
  3. Check continuity between ion generator harness connector and A/C-ECU harness connector.
    Ion generator
    A/C-ECU
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-43
    2
    C-06
    35
    Existed
  4. Check continuity between ion generator harness connector and body earth.
    Ion generator
    –
    Continuity
    Connector
    Terminal
    C-43
    2
    Body earth
    Not existed
Is the inspection result normal?
YES
Inspection end.
NO
Repair the harnesses or connectors.