DTC No. | M.U.T.-III SE screen terms (Trouble diagnosis content) | DTC detection condition | |
B24DE-15 | Ionizer supply (open circuit) (Ion generator) | Diagnosis condition | Ignition switch "ON" and blower motor ON. |
Signal (Terminal) | Ion generator power supply signal | ||
Threshold | Detects a current value of 20 mA or more does not flow in ion generator power supply signal | ||
Diagnosis delay time | 1 second or less | ||