ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - POWER OUTLET - WIRELESS CHARGER - TROUBLESHOOTING - SYMPTOM CHART - SYMPTOM PROCEDURES
Wireless charger symptom table
N514010900000100ENG
RELATED TO WIRELESS CHARGER
Make sure the wireless charger is not in a deactivation condition before starting diagnosis.
Symptoms
Check items
Possible malfunction location/Action to take
Wireless charging does not start
Ignition switch is not changed to ON.
Change ignition switch to ON.
Using non-Qi-certified smart phones
Smartphones not supporting Qi format are unable to charge wirelessly.
Using Qi-certified smart phones.
When a Qi-certified smart phone starts charging, an orange indicator lamp flashes. (The indicator lamp turns off after flashing for 8 seconds.)
  1. Confirm if any foreign matters are on the charging pad.
  2. If the wireless charger and/or smart phone are/is overheated, leave them/it to cool off.
  3. Perform self-diagnosis with M.U.T.-III SE. Perform detected DTC self-diagnosis. Refer to DIAGNOSIS CODE CHART.
The wireless charger indicator lamp does not turn ON/flash.
Wireless charger power supply and earth circuit malfunction. Refer to Diagnosis Procedure: Wireless charger power supply and earth circuit.