ELECTRICAL & POWER CONTROL - CONTROLLER AREA NETWORK (CAN) - TROUBLESHOOTING<CAN> - CAN BUS DIAGNOSIS - IT CAN COMMUNICATION CIRCUIT - SHORT CIRCUIT OR OPEN CIRCUIT
IT CAN 1 COMMUNICATION CIRCUIT
N514180850000300ENG
1.CONNECTOR INSPECTION
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Disconnect the battery cable from the negative terminal.
  3. Disconnect all the unit connectors on IT CAN 1 communication circuit.
  4. Check terminals and connectors for damage, bend and loose connection (unit side and harness side).
Is the inspection result normal?
YES
NO
Repair the terminal and connector.
2.CHECK HARNESS CONTINUITY (OPEN CIRCUIT)
Check the continuity between the gateway-ECU harness connector terminals.
Gateway-ECU harness connector
Continuity
Connector No.
Terminal No.
Connector No.
Terminal No.
C-112
27
C-112
30
Existed
26
29
Existed
Is the inspection result normal?
YES
NO
Check the harness and repair or replace the root cause.
3.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the gateway-ECU harness connector terminals.
Gateway-ECU harness connector
Continuity
Connector No.
Terminal No.
C-112
27
26
Not existed
Is the inspection result normal?
YES
NO
Check the harness and repair or replace the root cause.
4.CHECK HARNESS CONTINUITY (SHORT CIRCUIT)
Check the continuity between the gateway-ECU and the body earth.
Gateway-ECU harness connector
Body earth
Continuity
Connector No.
Terminal No.
C-112
27
Not existed
26
Not existed
Is the inspection result normal?
YES
NO
Check the harness and repair or replace the root cause.
5.CHECK GATEWAY-ECU TERMINATION CIRCUIT
  1. Remove the gateway-ECU.
  2. Check the resistance between the gateway-ECU terminals.
    Gateway-ECU
    Resistance (Ω)
    Connector No.
    Terminal No.
    C-112
    27
    26
    Approx. 108 – 132
    30
    29
    Approx. 108 – 132
Is the measurement value within the specification?
YES
NO
Replace the gateway-ECU. Refer to Electrical & Power Control – Controller Area Network (CAN) – Gateway-ECU – GATEWAY-ECU REMOVAL AND INSTALLATION.
6.CHECK SYMPTOM
Connect all the connectors. Check if the symptoms described in the “Symptom (Results from interview with customer)” are reproduced.
Inspection result
Reproduced
Non-reproduced
Start the diagnosis again. Follow the trouble diagnosis procedure when past error is detected.
7.CHECK UNIT REPRODUCTION
Perform the reproduction test as per the following procedure for each unit.
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Disconnect the battery cable from the negative terminal.
  3. Disconnect one of the unit connectors of IT CAN 1 communication circuit.
    NOTE:
    Gateway-ECU has termination circuit. Check other units first.
  4. Connect the battery cable to the negative terminal. Check if the symptoms described in the “Symptom (Results from interview with customer)” are reproduced.
    NOTE:
    Although unit-related error symptoms occur, do not confuse them with other symptoms.
Inspection result
Reproduced
Connect the connector. Check other units as per the above procedure.
Non-reproduced
Replace the unit whose connector was disconnected.
BookmarkedToo many bookmarks.
Please delete and bookmark again.