ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - DAYTIME RUNNING LAMP - TROUBLESHOOTING - SYMPTOM PROCEDURES - ONE OF THE DAYTIME RUNNING LAMPS DOES NOT ILLUMINATE NORMALLY<BULB TYPE>
Diagnosis Procedure: One of the daytime running lamps does not illuminate normally
N514230170000100ENG
1.BULB CHECK
Check the bulb(s) of the lamp that does not illuminate.
Is the inspection result normal?
YES
NO
Replace the bulb(s) of the lamp that does not illuminate (Refer to REPLACEMENT OF REPLACEABLE BULB).
2.RESISTANCE MEASUREMENT AT THE DAYTIME RUNNING LAMP (LH) CONNECTOR, DAYTIME RUNNING LAMP (RH) CONNECTOR (EARTH TERMINAL).
  1. Disconnect the connector, and measure at the wiring harness side.
  2. Measure the resistance between the connector of lamp which does not illuminate and the body earth.
    Daytime running lamps harness connector
    —
    Continuity
    Connector
    Terminal
    RH
    A-134
    2
    Body earth
    Continuity exists (2 Ωor less)
    LH
    A-132
Is the inspection result normal?
YES
NO
3.CHECK OF OPEN CIRCUIT IN EARTH LINE BETWEEN THE DAYTIME RUNNING LAMP (LH) CONNECTOR, DAYTIME RUNNING LAMP (RH) CONNECTOR AND BODY EARTH.
  1. Disconnect the connector.
  2. Check of open circuit in earth line between the daytime running lamp (LH) connector, daytime running lamp (RH) connector and body earth.
    Daytime running lamps harness connector
    —
    Continuity
    Connector
    Terminal
    RH
    A-134
    1
    Body earth
    Continuity exists (2 Ωor less)
    LH
    A-132
Is the inspection result normal?
YES
NO
Repair the connector(s) or wiring harness.
4.CHECK OF OPEN CIRCUIT IN OUTPUT LINE BETWEEN THE RELAY CONTROL UNIT CONNECTOR AND DAYTIME RUNNING LAMP (LH), DAYTIME RUNNING LAMP (RH) CONNECTOR.
  1. Disconnect the relay control unit connector and daytime running lamp connector.
  2. Check continuity between the relay control unit harness connector and daytime running lamp harness connector.
    Relay control unit harness connector
    Daytime running lamps harness connector
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    RH
    A-21
    2
    A-134
    2
    Existed
    LH
    A-23
    3
    A-132
Is the inspection result normal?
YES
NO
Repair the connector(s) or wiring harness.
5.Retest the system
Check that the daytime running lamp function normally.
Is the check result normal?
YES
To check malfunction symptom before repair: Refer to General information - Basic inspection - Service information for electrical incident - INTERMITTENT INCIDENT.
NO
Replace the corresponding daytime running lamps. Refer to DAYTIME RUNNING LAMP REMOVAL AND INSTALLATION.
BookmarkedToo many bookmarks.
Please delete and bookmark again.