ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - COMBINATION METER - TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - U1010-49 CONTROL UNIT(CAN)
DTC Description: U1010-49
N514280930000200ENG
DTC DETECTION LOGIC
DTC No.
M.U.T.-III SE screen terms
(Trouble diagnosis content)
DTC detected condition
U1010-49
CONTROL UNIT (CAN)
[Control unit (CAN)]
Diagnosis condition
When ignition switch is ON.
Signal (terminal)
—
Threshold
When detecting error during the initial diagnosis
Diagnosis delay time
2 seconds or more
POSSIBLE CAUSE
Combination meter
FAIL-SAFE
The combination meter activates the fail-safe control if CAN communication with each unit is malfunctioning.
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
  1. Turn ignition switch ON and wait for 2 seconds or more.
  2. Check “Self-diagnosis” of “METER/M&A.”
Is DTC U1010-49 detected?
YES
NO-1
To check malfunction symptom before repair: Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT.
NO-2
Confirmation after repair: INSPECTION END