ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - COMBINATION METER - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURES - AMBIENT TEMPERATURE SENSOR SIGNAL CIRCUIT
Diagnosis Procedure: Ambient temperature sensor signal circuit
N514281880000400ENG
1.CHECK AMBIENT TEMPERATURE SENSOR SIGNAL
  1. Turn ignition switch ON.
  2. Check voltage between combination meter harness connector terminal and body earth.
    (+)
    (−)
    Voltage
    Combination meter
    Connector
    Terminal
    C-11
    32
    Body earth
Is the inspection result normal?
YES
NO
2.CHECK AMBIENT TEMPERATURE SENSOR POWER SUPPLY
  1. Turn ignition switch OFF.
  2. Disconnect ambient temperature sensor connector.
  3. Turn ignition switch ON.
  4. Check voltage between ambient temperature sensor harness connector and body earth.
    (+)
    (−)
    Voltage
    (Approx.)
    Ambient temperature sensor
    Connector
    Terminal
    A-45
    1
    Body earth
    5 V
Is the inspection result normal?
YES
NO
3.CHECK AMBIENT TEMPERATURE SENSOR EARTH CIRCUIT FOR OPEN
  1. Turn ignition switch OFF.
  2. Disconnect combination meter connector.
  3. Check continuity between ambient sensor harness connector and A/C auto amp harness connector.
    Ambient temperature sensor
    Combination meter
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-45
    2
    C-11
    31
    Existed
Is the inspection result normal?
YES
NO
Repair harness or connector.
4.CHECK AMBIENT TEMPERATURE SENSOR
Check ambient temperature sensor. Refer to Heater, Air Conditioner and Ventilation – Heater, Air Conditioner And Ventilation – Ambient Temperature Sensor – AMBIENT TEMPERATURE SENSOR INSPECTION.
Is the inspection result normal?
YES
Replace combination meter Refer to COMBINATION METER REMOVAL AND INSTALLATION.
NO
Replace ambient temperature sensor. Refer to Heater, Air Conditioner and Ventilation – Heater, Air Conditioner And Ventilation – Ambient Temperature Sensor – AMBIENT TEMPERATURE SENSOR REMOVAL AND INSTALLATION.
5.CHECK AMBIENT TEMPERATURE SENSOR POWER SUPPLY CIRCUIT FOR OPEN
  1. Turn ignition switch OFF.
  2. Disconnect combination meter connector.
  3. Check continuity between ambient temperature sensor harness connector and combination meter harness connector.
    Ambient temperature sensor
    Combination meter
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-45
    1
    C-11
    32
    Existed
Is the inspection result normal?
YES
NO
Repair harness or connector.
6.CHECK AMBIENT TEMPERATURE SENSOR POWER SUPPLY CIRCUIT FOR SHORT
Check continuity between ambient temperature sensor harness connector and body earth.
Ambient temperature sensor
(-)
Continuity
Connector
Terminal
A-45
1
Body earth
Not existed
Is the inspection result normal?
YES
Replace combination meter Refer to COMBINATION METER REMOVAL AND INSTALLATION.
NO
Repair harness or connector.
7.CHECK INTERMITTENT INCIDENT
Check intermittent incident. Refer to Intermittent IncidentINTERMITTENT INCIDENT.
Is the inspection result normal?
YES
Replace combination meter Refer to COMBINATION METER REMOVAL AND INSTALLATION.
NO
Repair or replace malfunctioning parts.
BookmarkedToo many bookmarks.
Please delete and bookmark again.