ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - COMBINATION METER - TROUBLESHOOTING - SYMPTOM PROCEDURES - THE AMBIENT TEMPERATURE DISPLAY IS INCORRECT
Diagnosis Procedure: The ambient temperature display is incorrect
N514282070000300ENG
NOTE:
Check that the symptom is not applicable to the normal operating condition before starting diagnosis. Refer to Description: Normal operating condition.
1.CHECK AMBIENT TEMPERATURE SENSOR SIGNAL CIRCUIT
Check the ambient temperature sensor signal circuit. Refer to Diagnosis Procedure: Ambient temperature sensor signal circuit.
Is the inspection result normal?
YES
NO
Repair or replace malfunctioning parts.
2.CHECK COMBINATION METER INPUT SIGNAL
Select the “Data List” for the “METER/M&A” and check the “OUTSIDE TEMP” monitor value.
Is the inspection result normal?
YES
Replace combination meter. Refer to COMBINATION METER REMOVAL AND INSTALLATION.
NO
Replace ambient temperature sensor. Refer to Heater, Air Conditioner and Ventilation – Heater, Air Conditioner And Ventilation – Ambient Temperature Sensor – AMBIENT TEMPERATURE SENSOR REMOVAL AND INSTALLATION.