ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - ETACS - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURES - POWER SUPPLY AND EARTH CIRCUIT
Diagnosis Procedure: Power supply and earth circuit
N514311840000400ENG
1.CHECK FUSE
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Check that the following fuse is not blown (open).
    Unit
    Location
    Fuse No.
    Capacity
    ETACS-ECU
    Fuse block (J/B)
    30
    5A
    15
Is the fuse blown (open)?
YES
Replace the blown (open) fuse after repairing the affected circuit if a fuse is blown (open).
NO
2.CHECK POWER SUPPLY CIRCUIT
  1. Disconnect the ETACS-ECU connectors.
  2. Check the voltage between the ETACS-ECU harness connector and body earth.
    (+)
    (-)
    Voltage
    ETACS-ECU
    Connector
    Terminal
    C-210
    14
    Body earth
    9 – 16 V
    C-215
    3
Is the inspection result normal?
YES
NO
Repair harness or connector.
3.CHECK EARTH CIRCUIT
Check continuity between the ETACS-ECU harness connector and body earth.
ETACS-ECU
–
Continuity
Connector
Terminal
C-215
7
Body earth
Existed
15
Is the inspection result normal?
YES
INSPECTION END
NO
Repair harness or connector.
BookmarkedToo many bookmarks.