ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - INTERIOR LAMP - TROUBLESHOOTING - CIRCUIT DIAGNOSIS PROCEDURE - INTERIOR ROOM LAMP POWER SUPPLY CIRCUIT
Diagnosis Procedure: Interior room lamp power supply circuit
N514370190000800ENG
1.CHECK SYMPTOM
Check symptom (A or B).
A
All the following lights do not turn ON.
  • Front room lamp
  • Rear room lamp
  • Spot lamp
B
Interior lamp auto-cutout function does not activate.
A
B
2.CHECK FUSE
  1. Ignition switch OFF.
  2. Check that the following fuse is not blown (open).
    Location
    Fuse No.
    Capacity
    Fuse block (J/B)
    23
    10 A
Is the fuse blown (open)?
YES
Replace the blown (open) fuse after repairing the cause of blown (open).
NO
3.CHECK INTERIOR ROOM LAMP RELAY CONTROL CIRCUIT 1
Check voltage between ETACS-ECU harness connector and body earth.
(+)
(-)
Voltage
ETACS-ECU
Connector
Terminal
C-210
24
Body earth
Battery voltage
Is the inspection result normal?
YES
Replace fuse block (J/B).
NO
4.CHECK INTERIOR ROOM LAMP REALY CONTROL CIRCUIT 2
  1. Disconnect ETACS-ECU connector and fuse block (J/B) connector.
  2. Check continuity between ETACS-ECU harness connector and fuse block (J/B) harness connector.
    ETACS-ECU
    Fuse block (J/B)
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    C-210
    24
    C-318
    4
    Existed
Is the inspection result normal?
YES
NO
Repair or replace harness.
5.CHECK INTERIOR ROOM LAMP RELAY 1
Check interior room lamp relay. Refer to Component Inspection: Interior room lamp power supply circuit.
Is the inspection result normal?
YES
Replace fuse block (J/B).
NO
Replace interior room lamp relay.
6.CHECK INTERIOR ROOM LAMP RELAY 2
Check interior room lamp relay. Refer to Component Inspection: Interior room lamp power supply circuit.
Is the inspection result normal?
YES
NO
Replace interior room lamp relay.
7.CHECK INTERIOR ROOM LAMP RELAY CONTROL CIRCUIT 3
  1. Disconnect ETACS-ECU connector and fuse block (J/B) connector.
  2. Check continuity between ETACS-ECU harness connector and body earth.
    ETACS-ECU
    —
    Continuity
    Connector
    Terminal
    C-210
    24
    Body earth
    Not existed
Is the inspection result normal?
YES
NO
Repair or replace harnesses.
8.CHECK INTERIOR ROOM LAMP REALY CONTROL CIRCUIT 4
Check continuity between fuse block (J/B) connector and body earth.
Fuse block (J/B)
—
Continuity
Connector
Terminal
C-318
4
Body earth
Not existed
Is the inspection result normal?
YES
Replace ETACS-ECU. Refer to ETACS-ECU REMOVAL AND INSTALLATION.
NO
Replace fuse block (J/B).
BookmarkedToo many bookmarks.
Please delete and bookmark again.