1.CHECK SPOT LAMP POWER SUPPLY CIRCUIT
Ignition switch OFF.
Disconnect fuse block (J/B) connector and spot lamp connector.
Check continuity between fuse block (J/B) harness connector and spot lamp harness connector.
Fuse block (J/B) | Spot lamp | Continuity |
Connector | Terminal | Connector | Terminal |
C-320 | 10 | Front door RH | F-05 | 1 | Existed |
Front door LH | F-19 |
Is the inspection normal?
YES
NO
Repair or replace harness.
2.CHECK SPOT LAMP CONTROL SIGNAL CIRCUIT 1
Ignition switch ON.
Check continuity between ETACS-ECU harness connector and body earth.
ETACS-ECU | — | Condition | Continuity |
Connector | Terminal |
C-214 | 2 | Body earth | Driver side door | Open | Existed |
Close | Not existed |
Is the inspection result normal?
YES
NO-1
Continuity exists and remains unchanged:
GO TO 4.
NO-2
3.CHECK SPOT LAMP CONTROL SIGNAL CIRCUIT 2
Ignition switch OFF.
Disconnect ETACS-ECU connector.
Check continuity between ETACS-ECU harness connector and spot lamp harness connector.
ETACS-ECU | Spot lamp | Continuity |
Connector | Terminal | Connector | Terminal |
C-214 | 2 | Front door RH | F-05 | 2 | Existed |
Front door LH | F-19 |
Is the inspection result normal?
YES
NO
Repair or replace harnesses.
4.CHECK SPOT LAMP CONTROL SIGNAL CIRCUIT 3
Ignition switch OFF.
Disconnect ETACS-ECU connector.
Check continuity between ETACS-ECU harness connector and body earth.
ETACS-ECU | — | Continuity |
Connector | Terminal |
C-214 | 2 | Body earth | Not existed |
Is the inspection result normal?
YES
NO
Repair or replace harnesses.