BODY EXTERIOR, DOORS, ROOF & VEHICLE SECURITY - BODY - POWER WINDOW SYSTEM - TROUBLESHOOTING - SYMPTOM PROCEDURES - POWER WINDOWS DO NOT OPERATE WITH ANY POWER WINDOW SWITCHES
Diagnosis Procedure: Power windows do not operate with any power window switches
N519250760000100ENG
1.CHECK ETACS-ECU POWER SUPPLY AND EARTH CIRCUIT
Check ETACS-ECU power supply and earth circuit. Refer to Electrical & Power Control – Chassis Electrical – ETACS – Troubleshooting – Circuit Diagnosis Procedures – Diagnosis Procedure: Power supply and earth circuit.
Is the inspection result normal?
YES
NO
Repair or replace the malfunctioning parts.
2.CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND EARTH CIRCUIT
Check power window main switch power supply and earth circuit. Refer to Diagnosis Procedure: Power supply and earth circuit (Power window main switch).
Is the inspection result normal?
YES
NO
Repair or replace the malfunctioning parts.
3.CHECK POWER WINDOW MAIN SWITCH CIRCUIT (LIN COMMUNICATION CIRCUIT)
Check power window main switch circuit. Refer to Component Function Check: Power window main switch.
Is the inspection result normal?
YES
NO
Repair or replace the malfunctioning parts.
4.REPLACE POWER WINDOW MAIN SWITCH
  1. Replace power window main switch. Refer to POWER WINDOW MAIN SWITCH REMOVAL AND INSTALLATION.
  2. Confirm the operation again.
Is the inspection result normal?
YES
INSPECTION END
NO
Replace ETACS-ECU. Refer to Electrical & Power Control – Chassis Electrical – ETACS – ETACS-ECU REMOVAL AND INSTALLATION.
BookmarkedToo many bookmarks.
Please delete and bookmark again.