Accelerator pedal Position Sensor (APS) is integrated with accelerator pedal, and detects accelerator opening angle.
Engine-ECU uses the output voltage of this sensor to control appropriate fuel injection volume.
This APS is a non-contact type.
Structure and System
APS consists of a rotor fixed on pedal arm, and PCB assembly inserted into housing.
PCB assembly detects the rotor position using electromagnetic induction.
The APS has 2 output systems – APS (main) and APS (sub), and the output voltage is outputted to engine-ECU.
According to depression of the accelerator pedal, output voltage of the APS (main) and APS (sub) changes.
This allows engine-ECU to detect the actual accelerator pedal depression amount.
Engine-ECU uses APS (main) output voltage for appropriate fuel injection volume control.
The relationship between accelerator opening angle and output voltage of the APS (main) and APS (sub) is as shown in the figure below.
When Abnormality Is Detected
Engine-ECU compares output voltage of the APS (main) and APS (sub) to check for abnormality in sensor.
If the engine-ECU detects the abnormality, the emergency should be prevented by performing the fuel-safe control.