SYSTEM CONFIGURATION
In the common rail type fuel injection system, the pressurised fuel is supplied by the supply pump (high pressure fuel pump), stored in the common rail, and injected through the solenoid type fuel injectors.
Common rail stores the pressurised fuel (maximum of approximately 250 MPa) that is supplied by the supply pump (high pressure fuel pump).
This enables the system to maintain a stable injection pressure that is unaffected by the engine speed or load.
A fuel pressure relief valve is installed on the common rail.
When the fuel pressure in the common rail becomes extremely high, the fuel pressure relief valve opens, allowing the fuel to return to the fuel tank.
This protects the common rail system.