ELECTRICAL & POWER CONTROL - CHASSIS ELECTRICAL - EMERGENCY CALL SYSTEM (e-CALL) - COMPONENT PARTS
EMERGENCY CALL SPEAKER
N114340090000100ENG
Component Function Within The System
Outputs the operator's voice of the SOS call, etc. based on the audio signal from the telematic box control unit.
Rated input
: 1.5 W
Maximum input
: 3.0 W
Impedance
: 4.0 ± 0.6 Ω
Individual Component Function
Converts the electric (audio) signal to a voice.
Component Operation
The audio signal flows into the internal coil of the speaker, and the diaphragm connected to the coil vibrates to create a sound.
Component Parts Location
The emergency call speaker is installed in the instrument centre lower panel. Refer to GENERAL INFORMATION.