GENERAL INFORMATION - GENERAL - BASIC INSPECTION - M.U.T.-III SE CHECKING SYSTEM
M.U.T.-III SE DIAGNOSIS CONNECTOR CIRCUIT
N501011480000Z00ENG
INSPECTION PROCEDURE
If the M.U.T.-III SE cannot diagnose the system properly, check the following items.
Symptom
Check item
M.U.T.-III SE cannot access any system.
M.U.T.-III SE diagnosis connector power supply circuit (Terminal 16) and earth circuit (Terminal 4 and 5)
Check the power supply and earth circuit of gateway-ECU. Refer to
Diagnosis Procedure: Power supply and earth circuit
.
Check the diagnosis connector branch line circuit. Refer to
DIAGNOSIS CONNECTOR BRANCH LINE CIRCUIT
.
Check the diagnostic CAN communication circuit. Refer to
DIAGNOSTIC CAN COMMUNICATION CIRCUIT
.
If above inspection results are normal, replace gateway-ECU. Refer to
GATEWAY-ECU REMOVAL AND INSTALLATION
.
M.U.T.-III SE cannot access individual system. (Other systems can be accessed.)
Power supply and earth circuit for the control unit of the system (For detailed circuit, refer to wiring diagram for each system.)
Open or short circuit between the system and M.U.T.-III SE diagnosis connector (For detailed circuit, refer to wiring diagram for each system.)
Open or short circuit CAN communication line. Refer to
CAN BUS DIAGNOSIS PROCEDURE
.