INTAKE AIR TEMPERATURE SENSOR CHECKN502550280000500ENG
Disconnect the air flow sensor connector.
Measure the resistance between terminal No. 1 and No. 3.
Standard value:
13.6 to 18.4 kΩ (at –20°C)
2.21 to 2.69 kΩ (at 20°C)
0.493 to 0.667 kΩ (at 60°C)
Remove the air flow sensor.
Measure the resistance while heating the sensor using a hair drier.
Normal condition:
| | Temperature | Resistance | Higher | Smaller |
|
If the value deviates from the standard value or the resistance remains unchanged, replace the air flow sensor.
Install the air flow sensor and tighten it to the specified torque.
Tightening torque: 1.8 ± 0.6 N·m