(+) | (–) | Continuity | |
Turbine bypass valve actuator | |||
Connector | Terminal | ||
B-25 | 5 | Body earth | No continuity |
1 | |||
Turbine bypass valve actuator | Engine-ECU | ||
Connector | Terminal | Connector | Terminal |
B-25 | 5 | A-10 | 14 |
1 | 33 | ||
(+) | (–) | Voltage | |
Turbine bypass valve actuator | |||
Connector | Terminal | ||
B-25 | 4 | Body earth | Approximately 5 V |
(+) | (–) | Continuity | |
Turbine bypass valve actuator | |||
Connector | Terminal | ||
B-25 | 2 | Body earth | Continuity exists (2 Ω or less) |
(+) | (–) | Continuity | ||
Turbine bypass valve actuator | Engine-ECU | |||
Connector | Terminal | Connector | Terminal | |
B-25 | 3 | B-08 | 57 | Continuity exists (2 Ω or less) |