WATER CONTROL VALVE INSPECTION <EURO 6B OR EURO 6C>
N502570300000800ENG
VALVE OPEN TEMPERATURE AND VALVE LIFT AMOUNT INSPECTION
Obtain a container filled with water and place the water control valve in it with a stick (approximately 6 mm in diameter) inserted. Gradually warm up the water while stirring, and check that the water control valve opening temperature is within the standard value. The stick rises when the water control valve opens.
Standard value: 71°C ± 2°C
Warm up the water to the full-open temperature of the water control valve, and check that the valve lift amount is within the standard value.
Standard value:
80°C or more (Full-open temperature)
5 mm or more (Valve lift amount when it is fully opened)
NOTE:
Measure the height of the fully closed valve in advance, and then measure the valve height at fully open temperature to calculate the lift amount.
WATER CONTROL VALVE (THREE-WAY VALVE) INSPECTION
Connect the water supply hose (inner diameter 15 mm) to the pipe B of the water control valve.
Fix the water control valve in horizontal condition as shown in the illustration.
The valve operation when the valve is closed is normal if water colder than 30°C is slowly poured into pipe B and if water does not flow out from pipe A and C.
NOTE:
Passage of pipes A, B and C is connected, so a small amount of water flows out from pipes A and C, but this is normal.
The valve operation when the valve is opened is normal if hot water 80°C or hotter is slowly poured into pipe B and if the water flows out from pipe C.
WARNING:
Take caution not to get burned when pouring hot water into the pipe and by the water flowing out of the pipe.
NOTE:
The water control valve is equipped with a wax type thermo valve, so the flow rate of the pipe C varies depending on the temperature of the thermo valve.
Passage of pipes A, B and C is connected, so a small amount of water flows out from pipe A, but this is normal.