ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING
DATA LIST REFERENCE TABLE
N502630360000E00ENG
Item No.
Inspection Item
Inspection condition
Normal condition
1
Protection control operating state(urea injector 1)
  • Ignition switch: "ON" position.
  • Other than below.
OFF
During high exhaust gas temperature condition.
ON
2
Urea injector 1 tip temperature
Engine: Idle operation
Ambient temperature to 120°C
15
SCR system condition
During the initial check immediately after the startup.
Initial state
Under stand-by status after the initial check is completed.
The pressure control is not started (waiting for the exhaust gas temperature to rise, defrosting the urea water, etc.).
No pressure control
During pressure build-up.
Pressure build-up
During pressure control.
Pressure build-up completed
During pressure reduction control.
Decompression state
During pressure build-up.
Air venting condition
During first filling.
Initial replenishment state
The AdBlue® is being returned. (finished to be returned)
Sucking back completed state
The AdBlue® is being returned.
Sucking back state
Just IG-ON
Ignition ON state
16
SCR system sub condition
Other than below.
No sub state
Before pressure build-up.
Pressure build-up preparation
During pressure build-up.
Ventilation
During pressure reduction
Normal decompression
Decompression injector 1 open
During pressure sensor replacement
Pressure sensor replacement
During pressure reduction
Decompression injector 2 open
During air purging
System circulation
After finishing first filling
Successful initial filling
After finishing pressure reduction
Initial decompression state
During pressure reduction
Decompressed state
During pump valve open
Pump valve open state
During urea defrosting
Heat A(Urea tank-Piping)
Defrost confirm supply pump
Thaw confirm suction pump
Heat B(hydro connector)
Defrost confirm hydro connector
Urea pump re thawing
Defrost confirm urea pump
19
Urea backflow pump operating status
Other than below.
Deactivated
Low temperature condition (Ambient temperature or Urea tank temperature is below –7°C)
Freezing and defrosting
  • Engine is running.
  • After data list item No. 15: SCR system condition has changed to "pressure build-up".
  • When the ignition switch is turned to the "LOCK" (OFF) position from the "ON" position.
Pump active
Low temperature condition (Ambient temperature or Urea tank temperature is below –7°C)
Anti-freeze heating
When the ignition switch is turned to the "LOCK" (OFF) position from the "ON" position.
Backflow pump passage fully open
20
NOx sensor 1 signal enable flag
Other than below.
OFF
Engine: After warm-up, idle operation (After the dew point is reached).
ON
21
NOx sensor 3 signal enable flag
Other than below.
OFF
Engine: After warm-up, idle operation (After the dew point is reached).
ON
22
Ignition switch
Ignition switch: "LOCK" (OFF) position
OFF
Ignition switch: "ON" position
ON
23
PM sensor temperature
Engine: Idling after warming up the engine
When the exhaust gas temperature at the down stream SDPF is 150°C.
150°C
When the exhaust gas temperature at the downstream SDPF is 300°C.
300°C
When the exhaust gas temperature at the downstream SDPF is 450°C.
450°C
When the exhaust gas temperature at the downstream SDPF is 600°C.
600°C
When the exhaust gas temperature at the downstream SDPF is 750°C.
750°C
24
Urea tank frozen state
Other than below
Not frozen
Ambient temperature or Urea tank temperature ≦ –7°C
Temperature retention mode
Suspected tank freeze
Tank freeze detection
–
NONE
27
NOx sensor 1 heater operating
Other than below.
OFF
Engine: After warm-up, idle operation (After the dew point is reached).
ON
28
NOx sensor 3 heater operating
Other than below.
OFF
Engine: After warm-up, idle operation (After the dew point is reached).
ON
29
PM sensor heater operating
Other than below.
OFF
Engine: After warm-up, idle operation (After the dew point is reached).
ON
36
Service execution status
Other than below.
Not implemented
During "SCR system test"
Completed
Suspend
Running
37
Initial filling interruption
During "SCR system test"
Being implemented
When "SCR system test" is failed
DTC detected
Vehicle speed
Engine speed
Exhaust gas temperature high
Tank temperature drop
Urea tank level low
Battery voltage drop
Initial filling completed
Out of executable status range
Exceeded No. implementations
Suspended by IGN OFF
38
Urea pressure feed interruption
During "SCR system test"
Being implemented
When "SCR system test" is failed
DTC detected
Vehicle speed
Engine speed
Exhaust gas temperature high
Tank temperature drop
Urea tank level low
Battery voltage drop
Initial filling completed
Out of executable status range
Exceeded No. implementations
39
Decompression interruption
During "SCR system test"
Being implemented
When "SCR system test" is failed
DTC detected
Vehicle speed
Engine speed
Exhaust gas temperature high
Tank temperature drop
Urea tank level low
Battery voltage drop
Initial filling completed
Out of executable status range
40
Service status
Other than below.
Not implemented
During "SCR system test"
Initial filling completed
Ready for pressure
Decompression completed
42
Battery voltage
Ignition switch: "ON" position
Battery voltage
47
Tank defrosting judgment
Engine: Idle operation (Urea tank not frozen)
OFF
Engine: Idle operation (Urea tank frozen)
ON
49
Exhaust gas temperature upstream SCR catalyst 1
Engine: Idle operation after warm-up
When the exhaust gas temperature is 150°C.
150°C
When the exhaust gas temperature is 300°C.
300°C
When the exhaust gas temperature is 450°C.
450°C
When the exhaust gas temperature is 600°C.
600°C
When the exhaust gas temperature is 750°C.
750°C
51
Urea tank heater status
Other than below.
OFF
  • When the urea tank temperature is less than –7°C.
  • Within a predetermined time after the engine is started.
ON
53
Urea water first filling success
After DCU replacement
OFF
Other than above
ON
56
Vehicle speed
Running at 40 km/h.
Approximately 40 km/h
57
Engine operation status
–
STANDBY
Ignition switch: "ON" position
READY
–
CRANKING
Engine: Idle operation
RUNNING
–
STOPPING
STOPPED
58
Urea hose heater operate state
Other than below.
OFF
  • When the urea tank temperature is less than –7°C.
  • Within a predetermined time after the engine is started.
ON
59
Urea refill event is detected
Ignition switch: "ON" position
OFF
Ignition switch: "ON" position (Refill urea is detected)
ON
60
Backflow pump operating state
Other than below.
OFF
  • Engine is running.
  • After data list item No. 15: SCR system condition has changed to "pressure build-up".
  • When the ignition switch is turned to the "LOCK" (OFF) position from the "ON" position.
ON
61
Supply pump operating state
Other than below.
OFF
  • Engine is running.
  • After data list item No. 15: SCR system condition has changed to "pressure build-up".
ON
65
PM sensor detection time ratio
Engine is running after PM sensor is activated (after data list item No. 100: PM sensor status has changed to "Measurement").
0.000 to 1.000
66
Result for defect detection DPF
When diagnosis code No. P2002-00: DPF Flow Resistance Below Limit is detected
Less than 1.0
68
PM sensor status information(Dew point end reached)
Other than below.
OFF
Engine: After warm-up, idle operation (After the dew point is reached).
ON
69
Engine speed
  • Engine: Cranking
  • Tachometer: Connected
Compare engine speed on tachometer with the value displayed on M.U.T.-III SE.
Matched
  • Engine: Idle operation
  • Gearshift lever position: Neutral <M/T>
  • Selector lever position: "P" range <A/T>
  • A/C switch: OFF
When the engine coolant temperature is –20°C.
840 to 900 r/min
When the engine coolant temperature is 0°C.
770 to 830 r/min
When the engine coolant temperature is 25°C.
690 to 750 r/min
When the engine coolant temperature is 40°C.
When the engine coolant temperature is 80°C.
70
Coolant temperature
Ignition switch: "ON" position
or
Engine: Running
When the engine coolant temperature is –20°C.
–20°C
When the engine coolant temperature is 0°C.
0°C
When the engine coolant temperature is 25°C.
25°C
When the engine coolant temperature is 40°C.
40°C
When the engine coolant temperature is 80°C.
80°C
73
DPF regeneration mode
Other than below.
OFF
During DPF regeneration
ON
74
Fuel cut
Other than below.
OFF
Driving: Accel pedal released during vehicle running
ON
75
Boost pressure
Ignition switch: "ON" position
Altitude: 0 m
1,010 hPa
Altitude: 600 m
950 hPa
Altitude: 1,200 m
880 hPa
Altitude: 1,800 m
810 hPa
  • Engine coolant temperature: 85 to 95°C
  • Lamps and all accessories: OFF
  • Gearshift lever position: Neutral <M/T>
  • Selector lever position: "P" range <A/T>
When engine is suddenly raced.
The value changes according to the pressure inside the inlet manifold.
76
Air flow sensor value
Ignition switch: "ON" position
0 kg/h
Engine: Running
0 kg/h or more
77
EGR rate
Engine: Running
0 to 100
78
EGR valve opening degree
Ignition switch: "ON" position
or
Engine: Running
0 to 100 %
81
Vehicle acceleration(front/rear G)
Vehicle stopped (level)
–0.4 to 0.4 m/s2
Running
–9.8 to 9.8 m/s2
82
Vehicle acceleration(lateral G)
Vehicle stopped (level)
–1.1 to 1.1 m/s2
Running
–9.8 to 9.8 m/s2
84
Gear position <A/T>
Selector lever: "P" or "N" position
N or P
Selector lever: Sport mode
Driving at a constant speed of 10 km/h in 1st
1st
Driving at a constant speed of 20 km/h in 2nd
2nd
Driving at a constant speed of 40 km/h in 3rd
3rd
Driving at a constant speed of 60 km/h in 4th
4th
Driving at a constant speed of 70 km/h in 5th
5th
Driving at a constant speed of 80 km/h in 6th
6th
85
Accelerator pedal opening degree
Ignition switch: "ON" position
0 to 100%
86
Brake signal
Ignition switch: "ON" position
Brake pedal: Released
OFF
Brake pedal: Depressed
ON
87
Ambient pressure
Ignition switch: "ON" position
Altitude: 0 m
1,010 hPa
Altitude: 600 m
950 hPa
Altitude: 1,200 m
880 hPa
Altitude: 1,800 m
810 hPa
88
Throttle valve opening degree
Ignition switch: "ON" position
0 to 100%
90
Urea injection control status
Other than below
Stop urea injection
Engine: After warm-up, After data list item No. 5:SCR1 catalyst average temperature is reached to 180°C.
Permission for urea injection
During urea dosing limitation is active.
Restricted (NH3 slip)
During DPF regeneration
Stop (DPF regen requirement)
Urea inj permit (regen prog)
Stop(DPF regen temperature high)
During urea dosing limitation is active.
Restricted(exh system fail)
Stop (regen required exh fail)
Restricted (exh fail DPF regen)
91
Urea level sensor status
Other than below.
No signal
Signal NG(short time)
Ignition switch: "ON" position (Urea tank level sensor is available)
Signal OK(reception low)
Signal OK(reception medium)
Signal OK(reception high)
Signal OK(maximum reception)
92
Urea temperature sensor status
Other than below.
Not available
Ignition switch: "ON" position (Urea tank temperature sensor is available)
Available
93
Urea concentration signal status
Other than below.
NG(no signal)
NG(sonar low quality)
NG(sonar low constant)
Ignition switch: "ON" position (Urea concentration sensor is available)
OK(sonar high quality small)
OK(sonar high quality medium)
OK(sonar high quality large)
96
Urea concentration
Ignition switch: "ON" position
Around 32.5%
97
Duty of electrical water pump
Other than below.
0%
Ignition switch: soon after "LOCK" (OFF) position
17%
100
PM sensor status
During PM sensor regeneration
Initialize(Sensor regeneration)
Engine: After warm-up, idle operation (After the dew point is reached).
Measurement
Engine is running (Before the dew point is reached).
Sensor not ready
After finishing PM sensor regeneration
Regeneration finished
102
EGR valve rate
Ignition switch: "ON" position
or
Engine: Running
0 to 100%
103
Exhaust gas temperature sensor 1
Engine: Idle operation after warm-up
When the exhaust gas temperature is 150°C.
150°C
When the exhaust gas temperature is 300°C.
300°C
When the exhaust gas temperature is 450°C.
450°C
When the exhaust gas temperature is 600°C.
600°C
When the exhaust gas temperature is 750°C.
750°C
104
Exhaust gas temperature sensor 2
Engine: Idle operation after warm-up
When the exhaust gas temperature is 150°C.
150°C
When the exhaust gas temperature is 300°C.
300°C
When the exhaust gas temperature is 450°C.
450°C
When the exhaust gas temperature is 600°C.
600°C
When the exhaust gas temperature is 750°C.
750°C
105
Exhaust gas temperature sensor 3
Engine: Idle operation after warm-up
When the exhaust gas temperature is 150°C.
150°C
When the exhaust gas temperature is 300°C.
300°C
When the exhaust gas temperature is 450°C.
450°C
When the exhaust gas temperature is 600°C.
600°C
When the exhaust gas temperature is 750°C.
750°C
108
DPF operation status
Other than below.
Normal mode
During DPF regeneration
Regeneration mode
Before SCR catalyst warm
SCR Catalyst warm up mode
DCU Monitorring Items
  • This monitor item includes useful items for understanding the urea SCR system controlled by the DCU.
  • It is hard to show the definite specification of each item. Therefore, this document describes the check conditions, display range, and behaviour of numeric values only.
Item No.
Inspection item
M.U.T.-III SE display descriptions
Standards at each check
Display range, and numeric value
3
SCR1 ammonia absorption
Calculated amount of ammonia adsorbed in the main catalytic converter (SCR-DPF)
Engine: Idle operation
0 g or more
4
SCR2 ammonia absorption
Calculated amount of ammonia adsorbed in the catalytic converter (SCR)
Engine: Idle operation
0 g or more
5
SCR1 catalyst average temperature
Main catalytic converter (SCR-DPF) average temperature value calculated from exhaust gas temperature sensor values, etc.
Engine: Idle operation
Ambient temperature to 750°C
6
SCR2 catalyst average temperature
Average catalytic converter (SCR) temperature value calculated from exhaust gas temperature sensor value, etc.
Engine: Idle operation
Ambient temperature to 750°C
7
Urea consumption rate
Average consumption rate for the last 2,400 km travelled
Engine: Idle operation
0 to 10 g/km
8
Exhaust gas flow rate
Exhaust gas flow values received from the Engine-ECU via CAN communication.
Engine: Idle operation
0 kg/h or more
9
NOx sensor 1 received heat quantity
Value of the heat amount that NOX sensor No. 1 received from the exhaust gases from the start of the engine.
Engine: Idle operation
0 kJ or more
10
NOx sensor 3 received heat quantity
Value of the heat amount that NOX sensor No. 3 received from the exhaust gases from the start of the engine.
Engine: Idle operation
0 kJ or more
11
PM sensor received heat quantity
Value of the heat amount that PM sensor received from the exhaust gases from the start of the engine.
Engine: Idle operation
0 kJ or more
12
NOx sensor 1 heat quantity threshold
Threshold value of the heat amount that NOX sensor No. 1 received from the exhaust gases from the start of the engine.
Engine: Idle operation
0 kJ or more
13
NOx sensor 3 heat quantity threshold
Threshold value of the heat amount that NOX sensor No. 3 received from the exhaust gases from the start of the engine.
Engine: Idle operation
0 kJ or more
14
PM sensor heat quantity threshold
Threshold value of the PM sensor received from the exhaust gases from the start of the engine.
Engine: Idle operation
0 kJ or more
17
Urea tank level
Detected value of urea tank level sensor
Ignition switch: "ON" position
0 to 160 mm
18
Urea injector 1 desired dosing quantity
Indicated injection volume of urea water calculated by the DCU based on NOx emissions
Engine: Idle operation
0 mg/s or more
25
Estimated ammonia concentration downstream SCR1
Concentration of ammonia flowing out to the downstream of the SCR-DPF in the main catalytic converter (DCU calculated value)
Engine: Idle operation
0 ppm or more
26
Estimated ammonia concentration downstream SCR2
Concentration of ammonia flowing out to the downstream of the SCR in the catalytic converter (DCU calculated value)
Engine: Idle operation
0 ppm or more
30
Urea tank heater current
Urea tank heater current value when driven
Engine: Idle operation
0 to 30 A
31
Urea tube heater current
Urea tube heater current value when driven
Engine: Idle operation
0 to 15 A
32
Supply pump current value
Supply pump current value when driven
Engine: After warm-up, idle operation
0 to 3,000 mA
33
Back flow pump current value
Back flow pump current value when driven
Engine: After warm-up, idle operation
0 to 3,000 mA
34
Urea total injection quantity 1
Total amount of urea injection from the condition when the DCU is replaced with a new one.
Engine: Idle operation
0 to 429,496,729,500 mg
35
Total mileage
Total distance travelled by the vehicle from the condition when the DCU is replaced with a new one.
Ignition switch: "ON" position
0 to 4,294,967,295 m
41
Urea tank temperature
Value of the tank temperature sensor on the urea pump
Ignition switch: "ON" position
–40 to 80°C
43
Urea tank remaining volume(%)
Remaining urea tank volume (displayed in %)
Ignition switch: "ON" position
0 to 100 %
44
Urea tank remaining volume(L)
Remaining urea tank volume (displayed in litres)
Ignition switch: "ON" position
0 to 18.47 L
45
Urea tank remaining volume(g)
Remaining urea tank volume (displayed in grams)
Ignition switch: "ON" position
0 to 21,000 g
46
Urea tank level sensor(filtered value)
Detected value of urea tank level sensor (filter value)
Ignition switch: "ON" position
0 to 160 mm
48
SCR catalyst efficiency
Value of NOx purification efficiency calculated from NOx sensor No. 1 and NOx sensor No. 3 values.
Engine: Idle operation
0.0 to 1.0
50
Urea pressure sensor(filtered value)
Detected value of urea pressure sensor (filter value)
Engine: After warm-up, idle operation (Data list item No. 15: SCR system condition = Pressure build-up completed)
5,000 to 7,000 hPa
52
Urea injector 1 drive duty
Urea injector drive duty value
Engine: After warm-up, idle operation
0 to 100
54
Mileage after DCU replacement
Driving distance since DCU replacement
Ignition switch: "ON" position
0 to 2,147,483,647 m
55
Urea tank level sensor(raw value)
Detected value of urea tank level sensor
Ignition switch: "ON" position
0 to 160 mm
62
NOx sensor 1 detect concentration
NOx concentration detected by NOx sensor No. 1
Engine: After warm-up
0 to 33,000 ppm
63
NOx sensor 3 detect concentration
NOx concentration detected by NOx sensor No. 3
Engine: After warm-up
0 to 33,000 ppm
64
Total fuel injection quantity(1 cycle)
Indicates the integrated fuel injection quantity in 1 cycle (pilot injection, pre-injection, main injection, after-injection, post injection).
Engine: Idle operation
0 to 1,020 mg/hub
67
DPF soot deposition
Indicates the DPF soot accumulation.
Ignition switch: "ON" position
0 to 12.75 g
71
Ambient temperature
Indicates the ambient temperature.
Ignition switch: "ON" position
–40 to 80°C
72
Target torque
Indicates the target torque.
  • Engine: Idle operation (after warm-up)
  • Lamps and all accessories: OFF
  • Transmission: Neutral <M/T> or "P" range <A/T>
–150 to 500 Nm
79
Remaining mile urea refill warning
Distance that can be travelled until the remaining urea water level becomes empty.
Ignition switch: "ON" position
0 to 17,000 km
80
O2 value(NOx sensor 1)
Oxygen concentration detected by NOx sensor No. 1
Engine: Idle operation [After NOx sensor No. 1 is ON (data list item No. 27: NOx sensor 1 heater operating: ON)]
0 to 0.21
83
Driving distance after regeneration
Distance travelled since the completion of the last DPF regeneration
Ignition switch: "ON" position
0 to 2,147,483,647 m
89
O2 value(NOx sensor 3)
Oxygen concentration detected by NOx sensor No. 3
Engine: Idle operation [After NOx sensor No. 3 is ON (data list item No. 28: NOx sensor 3 heater operating: ON)]
0 to 0.21
94
Urea pressure sensor(filter value)
Detected value of urea pressure sensor (filter value)
Engine: After warm-up, idle operation (Data list item No. 15: SCR system condition = Pressure build-up completed)
5,000 to 7,000 hPa
95
Fuel injection quantity
Indicates the command fuel injection quantity.
Engine: Idle operation
0 to 120 mg/hub
98
SCR1 target ammonia absorption
Target amount of ammonia to be adsorbed by the main catalytic converter (SCR-DPF)
Engine: Idle operation
0 g or more
99
SCR2 target ammonia absorption
Target amount of ammonia to be adsorbed by the catalytic converter (SCR)
Engine: Idle operation
0 g or more
101
PM sensor current
Current value flowing at the electrodes of the PM sensor
Engine: After warm-up
0 uA or more
106
Number of moving detection of urea injector 1 valve
Number of times the valve inside the urea injector is operating correctly.
Engine: Idle operation
0 count or more
107
Urea supply pump current(Pump lift stopped)
Current value detected when the solenoid inside the supply pump reaches the end of its range of motion.
Engine is running (After data list item No. 15: SCR system condition has changed to "pressure build-up").
0 mA or more
109
Urea consumption error factor
Value indicating the degree of deviation between urea water pump discharge and injection volume.
Engine: Idle operation
0.69 to 1.35
BookmarkedToo many bookmarks.
Please delete and bookmark again.