Operation Check
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
Connect the M.U.T.-III SE to the diagnosis connector.
Turn the ignition switch to the "ON" position.
Select "UDCU" from System Select Screen of the M.U.T.-III SE.
From UDCU Screen, select "Special Function".
From Special Function Screen, select "Test".
Execute "Item No. 2: Urea line emptying test" on the test screen and depressurise the urea feed tube.
Remove the urea tank protector (front side and under) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
CAUTION:
  • When disconnecting the urea line tube, follow the steps below to prevent AdBlue® leaks.
    • If solid AdBlue® is adhered to the connection, wipe it off with a wet cloth.
    • Clean the mud around the urea line tube C.
    • Put the disconnected urea line tube in a plastic bag respectively to prevent dust from adhering to them.
  • If the AdBlue® is adhered to the vehicle, wipe the area with a wet cloth.
Disconnect the urea line tube C from the urea pump.
Execute "Item No. 4: Urea pumping and Dosing test" on the test screen.
Check the status of the AdBlue® discharged from the urea pump.
Standard value: AdBlue® is discharged from the urea pump.
Press the stop button to terminate the urea pumping and injection test.
NOTE:
If the urea pumping and injection test is continued, the DCU determines that the pressure has dropped and the test will be terminated abnormally even if the system is normal.
If the AdBlue® is not discharged from the urea pump, replace the urea tank (integrated with urea pump) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
Connect the urea line tube C, and install the urea tank protector (front side and under) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
Check The Pump Resistance
Remove the urea tank protector (front side and under) (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
CAUTION:
Put the disconnected connector in a plastic bag respectively to prevent dust from adhering to them.
Disconnect the urea pump module connector.
Supply pump: Measure the resistance between terminal No. 4 and No. 5 at the urea pump module connector.
Standard value: 3.55 to 4.15 Ω (at 20°C)
Back flow pump: Measure the resistance between terminal No. 6 and No. 7 at the urea pump module connector.
Standard value: 3.44 to 4.04 Ω (at 20°C)
If resistance is outside the standard value, replace the urea pump (Refer to UREA TANK DISASSEMBLY AND REASSEMBLY).
Connect the urea pump module connector, and install the urea tank protector (front side and under).