ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P203A-1F Reductant level sensor A
DTC Description: P203A-1F
N502631320000G00ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P203A-1F
Reductant level sensor A
[No echo error of urea level sensor]
Diagnosis condition
  • Ignition switch is "ON" position.
  • DCU supply voltage is 10 to 16 V.
  • At least 5 seconds has passed since the DCU was activated.
  • Urea tank temperature is –1 °C or more.
  • Urea tank volume is 1,602 to 20,000 g.
  • Vehicle acceleration is below threshold.
    • The threshold depends on urea tank level:
      • tank level 80 mm -> 1.065 m/s2
      • tank level 200 mm -> 0.667 m/s2
Signal (terminal)
Urea level sensor
Threshold
Number of echoes received while vehicle is driven 12.5 km is less than 10 times.
Diagnosis delay time
Vehicle is driven 12.5 km
POSSIBLE CAUSE
  • Failed urea tank assembly [integrated with urea pump module (TLC sensor)].
  • Failure due to non-AdBlue® supplementation (freezing, crystallisation, foaming)
NOTE:
  • TLC sensor: Temperature/Level/Concentration sensor
  • The Urea pump module transmits the three TLC sensors' information on one SENT communication line.
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P203A-1F set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.