The operating time of the urea injector cooling system is calculated from the values of exhaust temperature sensor No. 2 and A/C condenser temperature sensor (ambient temperature sensor). After repairing the urea injector assembly, check that there is no malfunction in the exhaust temperature sensor No. 2 and the ambient temperature sensor, as the cause of the failure of the urea injector assembly may be due to the urea injector cooling system not working.