(+) | (–) | Voltage | |
DCU | |||
Connector | Terminal | ||
A-129 | 9 | Body earth | 1 V or less |
31 | |||
DCU | DCU | Continuity | ||
Connector | Terminal | Connector | Terminal | |
A-129 | 9 | A-129 | 1 | No continuity |
3 | ||||
5 | ||||
66 | ||||
89 | ||||
31 | 1 | |||
3 | ||||
5 | ||||
66 | ||||
89 | ||||
DCU | Urea injector assembly | Damage check | ||
Connector | Terminal | Connector | Terminal | |
A-129 | 9 | B-40 | 2 | Good condition |
31 | 1 | |||