ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20EA-00 Reductant control module power relay
Diagnosis Procedure: P20EA-00
N502632140000K00ENG
1.Check fusible link
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Check the following fusible link in the fusible link, fuse holder.
    Location
    Signal name
    Fusible link No.
    Capacity
    Fusible link, fuse holder
    Urea SCR relay
    SBF3
    60 A
Is the check result normal?
YES
NO
Perform the procedures for a blown fuse (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – INSPECTION SERVICE POINTS FOR A BLOWN FUSE).
2.Check urea SCR relay itself
Check urea SCR relay itself (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – RELAY INSPECTION).
Is the check result normal?
YES
NO
Replace the urea SCR relay.
3.Check power supply circuit between urea SCR relay connector and DCU connector
  1. Disconnect electric urea SCR relay connector and DCU connector.
  2. Check the harness connector side.
  3. Check continuity between urea SCR relay connector and DCU connector.
    (+)
    (–)
    Continuity
    Urea SCR relay
    DCU
    Connector
    Terminal
    Connector
    Terminal
    A-61
    3
    A-129
    23
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-61
    3
    A-129
    23
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
4.Check fuse
  1. Turn the ignition switch to the "LOCK" (OFF) position.
  2. Check the following fuse in the fusible link, fuse holder 2.
    Location
    Signal name
    Fuse No.
    Capacity
    Fusible link, fuse holder 2
    DCU
    F27
    15 A
Is the check result normal?
YES
NO
Perform the procedures for a blown fuse (Refer to General Information – General – How to Use This Manual – How to Use This Manual: Troubleshooting – INSPECTION SERVICE POINTS FOR A BLOWN FUSE).
5.Check continuity of DCU power supply line
  1. Disconnect the urea SCR relay connector and DCU connector.
  2. Check the harness connector side.
  3. Check continuity between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Continuity
    Connector
    Terminal
    Connector
    Terminal
    A-61
    4
    A-129
    3
    Continuity exists (2 Ω or less)
  4. Check harness wire and connector damage between urea SCR relay connector and DCU connector.
    Urea SCR relay
    DCU
    Damage check
    Connector
    Terminal
    Connector
    Terminal
    A-61
    4
    A-129
    3
    Good condition
Are the check result normal?
YES
NO
Repair or replace the connector, or repair the damaged harness wire.
6.Diagnosis code recheck after erasing diagnosis code
  1. Turn the ignition switch to the "ON" position. (Engine is not running.)
  2. Turn the ignition switch to the "LOCK" (OFF) position and wait at least 3 minutes.
  3. Turn the ignition switch to "ON" position and wait at least 10 seconds.
  4. Repeat Steps 2 to 3 twice.
  5. Check if the diagnosis code is set again (Refer to DTC Description: P20EA-00).
Is diagnosis code No. P20EA-00 set?
YES
Disconnect the DCU connector, then reconnect it securely.
NO
Intermittent malfunction (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).