ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20F5-00 Reductant consumption
DTC Description: P20F5-00
N502632250000100ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P20F5-00
Reductant consumption
[Urea injection volume is too high compared with feeding volume of urea pump]
Diagnosis condition
  • Ignition switch is "ON" position.
  • At least 1 second has passed since the DCU was activated.
  • After 1 g of urea is dosed since the dosing was possible.
  • The number of supply pump lift is reached to 300.
Signal (terminal)
–
Threshold
50 % of deviation between urea dosing quantity and supply pump delivery volume (Dosing quantity > Supply pump volume).
Diagnosis delay time
None.
POSSIBLE CAUSE
  • Failed urea feed tube A and/or B (leakage)
  • Failed urea injector assembly (injector stuck in open state, leakage)
  • Failed urea injector cooling system (clogging in cooling passage, failed water control valve, leakage in urea injector due to overheat)
  • Failed urea pump (integrated with urea supply pump and urea back flow pump) (failed urea supply pump, urea back flow pump stuck in open state、leakage in piping inside urea pump).
  • Failed DCU
FAIL-SAFE AND BACKUP FUNCTION
Urea SCR system shutdown → Urea dosing is stopped.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position.
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P20F5-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.
Please delete and bookmark again.