ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P20FA-13 Reductant pump B
DTC Description: P20FA-13
N502632340000800ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P20FA-13
Reductant pump B
[Urea back flow pump circuit open]
Diagnosis condition
  • Ignition switch is "ON" position.
  • At least 5 second has passed since the engine was started.
  • Battery positive voltage is more than 10 V and is less than 16 V.
  • Pressure buildup is started.
Signal (terminal)
Urea back flow pump.
Threshold
An open circuit in the urea pump (back flow pump) circuit is detected for 2 seconds or more.
Diagnosis delay time
2 seconds
POSSIBLE CAUSE
  • Open circuit or harness damage in urea pump (urea back flow pump) circuit or loose connector contact.
  • Failed urea pump (integrated with urea back flow pump).
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. 5 seconds or more later after the ignition switch has been in "ON" position
  2. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P20FA-13 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.