ENGINE - ENGINE AND EMISSION CONTROL - EMISSION CONTROL<4N1> - UREA SCR SYSTEM<EURO 6B OR EURO 6C> - UREA SCR TROUBLESHOOTING - DIAGNOSIS CODE PROCEDURES - P23AB-00 No.3 NOx Sensor Processor Performance
DTC Description: P23AB-00
N502632670000700ENG
DIAGNOSIS CODE DETECTION LOGIC
Diagnosis Code No.
M.U.T.-III SE Screen Item
[Diagnosis item]
Diagnosis Code Detection Condition
P23AB-00
No.3 NOx Sensor Processor Performance
[NOx sensor No. 3 processor performance]
Diagnosis condition
  • Sensing by the NOx sensor No. 3 is possible or at least 180 seconds have passed since the heater was energised.
  • Engine is running.
  • The change in the fuel injection amount is 6 mg/st or less (Injection quantity is stabilized).
  • Battery voltage is 10.9 to 16 V.
  • Exhaust gas temperature sensor No.3 (downstream SCR-DPF) is –50 to 500 °C.
  • The excess air ratio is 1.3 or more (lean state).
Signal (terminal)
NOx sensor No. 3
Threshold
The operation ratio of the NOx sensor No. 3 remains to be 30 % or less for 180 seconds or more (determined every 60 seconds).
Diagnosis delay time
180 seconds.
POSSIBLE CAUSE
Failed NOx sensor No. 3.
FAIL-SAFE AND BACKUP FUNCTION
None.
DIAGNOSIS CODE CONFIRMATION PROCEDURE
1.Preconditioning
If "Diagnosis Code Confirmation Procedure" has been previously conducted, always turn the ignition switch to the "LOCK" (OFF) position and wait at least 180 seconds before conducting the next test.
2.Diagnosis code confirmation procedure
CAUTION:
To prevent damage to the M.U.T.-III SE, always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the M.U.T.-III SE.
With M.U.T.-III SE
  1. Engine running.
  2. Check the following DCU data list item using M.U.T.-III SE (Refer to DATA LIST REFERENCE TABLE).
    • Data list item No. 21: NOx sensor 3 signal enable flag
      OK: ON
  3. Perform "Self-diagnosis" of DCU using M.U.T.-III SE.
Is diagnosis code No. P23AB-00 set?
YES
NO-1
To check malfunction symptom before repair: Check intermittent incident (Refer to General Information – General – Basic Inspection – Service Information for Electrical Incident – INTERMITTENT INCIDENT).
NO-2
Confirmation after repair: Inspection end.
BookmarkedToo many bookmarks.