Diagnosis Code No. | M.U.T.-III SE Screen Item [Diagnosis item] | Diagnosis Code Detection Condition | |
P24B3-12 | PM Sensor Heater Control Circuit High [PM sensor heater control circuit high] | Diagnosis condition |
|
Signal (terminal) | PM sensor | ||
Threshold | The self-diagnosis result indicating heater circuit high abnormality is received from the PM sensor via CAN communication for 3 seconds or more. | ||
Diagnosis delay time | 3 seconds. | ||